Ballbar testing is the first step in our metrology process. It shows how the axes of a machine tool interact under motion, and it sets the baseline for everything that follows. Where a ballbar result shows a positioning or reversal problem on a linear axis, we measure that axis directly with a laser interferometer. The Renishaw XL-80 is the instrument we use for that job.
Our engineers have worked on multi-axis machine tools since 2000. This article explains what the XL-80 measures, how a measurement is set up, and how the results feed repair, retrofit and acceptance decisions.
What the XL-80 Measures
The XL-80 is a laser interferometer. It measures the position of a machine axis against a traceable length reference: the wavelength of the laser light. Renishaw’s published specifications for linear measurement are:
- A measuring range of up to 80 m.
- Linear measurement accuracy of ±0.5 ppm over the full environmental range, with environmental compensation applied.
- Laser frequency accuracy of ±0.05 ppm over three years.
- Readings at up to 50 kHz, a maximum linear measurement speed of 4 m/s and a linear resolution of 1 nm.
With additional optics, the same system measures straightness, angular and squareness errors, and rotary axes with a rotary calibrator. Which optics a job needs is agreed before we arrive.
How the Measurement Works
The laser head sits at one end of the axis, and a reflector moves with the machine carriage. The beam travels to the reflector and back. The system counts the changes in the interference pattern as the carriage moves and converts them into a position reading. That reading is compared with the commanded position at each target point along the travel, in both directions.
The software records the position, the air conditions and a time stamp at every target point.
Set-Up and Environment
Air temperature, pressure and humidity all change the wavelength of the laser light, and so change the reading. An environmental compensator measures these conditions and corrects the wavelength in the calculation. For linear accuracy measurements we always use environmental compensation, so the result describes the machine, not the air.
The measurement also depends on the beam being aligned along the axis. Poor alignment shows up as an error in the result, so we check alignment before we record any data.
Reading the Results
A linear measurement produces a positioning error curve across the full axis travel. From that curve we read three things:
- Positioning error: the difference between the commanded and the measured position at each target.
- Reversal error: the difference in position when the axis approaches a target from the opposite direction.
- Repeatability: the spread of readings when the axis returns to the same target several times.
We report the results in ISO 230-2 format, written so that a production manager, a programmer and an operator can all read the same numbers.
From Measurement to Decision
The result points to one of three actions:
- Within tolerance: the axis stays in production, with a scheduled re-check.
- Outside tolerance, mechanical cause: the mechanics are repaired first. A control change will not correct a mechanical fault.
- Outside tolerance, control or drive cause: the error can often be reduced with the control’s compensation tables, or the control and drives become part of a retrofit plan.
We apply compensation only where the measured data supports it. Compensation does not hide a mechanical fault, and we say so when one needs fixing first.
Limits of the Method
The XL-80 measures the linear positioning of one axis at a time. It does not show how two or more axes behave together under motion. Contouring errors, servo mismatch and the interaction between axes need a ballbar test. That is why the ballbar comes first in our process, and the laser is used where the ballbar result calls for a closer look at a single axis. How we measure before a retrofit or repair.
Next Step
If you want to know how your machine performs, we can start with a ballbar test. Where the result points to a linear axis, we follow up with a laser measurement. We report, explain the options, and you decide what happens next. The first conversation is technical and carries no obligation. More about our machine tool metrology.